2019-05-31 Sigfox TX/RX test

Test equipment

1 test fixture (provide by PIE)

2 Spectrum Analyzer (e.g E4405B)

3.Vector Signal Generator (e.g E4438C)

4.3dB power splitter combiner

5.898/902/920MHz antenna

6.RF cable x 3

7.PC and Serial port line (3.3V)

8.Sigfox Module :WISOL / WSSFM10R1AT

RF Specifications :

4268168-191e319e7c3bc758.png
image

The instrument connection

4268168-8e400cb81aca4036.png
image

Spectrum Analyzer Setting:

4268168-d1fa62a3588ac05e.png
image

Sigfox serial port Settings

BaudRate Setting: 9600, 8N1, all AT command send to product has to be ended by ‘\r’ (CR)

TX test:

1 put the gold sample into the test fixture,measure Power and RSSI, and store it as calibration data

2 sending ‘’AT$DR? ‘’ to product

3 sending Tx on command (AT$CW=xxxxx,m,n)

4 Enter :Spectrum Analyzer marker peak search and recording the power and frequency

5 Calculate the frequency PPM

4268168-b3d889041ec8ae9b.png
image

6 sending Tx off command

7 test ok

RX test

1 Vector Signal Generator Setting:

4268168-31d49749a87015c8.png
image

2 Send Rx start command to the product: AT$TM=3,10. After sending this command, the product will not receive any command in the receiving mode, until 10 seconds later, the product will be returned to the product

** 3 **Signal generator: RF on (after about ten seconds )

** 4** Trigger Signal Generator sending the data once

5 receive data (RX data and RSSI)

6 Signal generator :RF Off


猜你喜欢